Ecobee y1 not working Twisting these in a wire nut did not turn on my system. I don’t have a G wire but there is a green wire that runs to the ac unit, just not connected. Scheduled an appointment with an HVAC technician as the ecobee support believes this is an issue with the furnace. Oct 5, 2024 · How Ecobee SmartSensors Work. Since I wrote the post, I connected Y1 and G to the existing AC wiring, reconfigured the Ecobee for AC, but not sure it's working. Wait, "only 2 wires coming to the thermostat" does not jive with: "The wires I have currently are: RC G Y1 C and W1" If you actually have those 5 wires going to the thermostat, you can re-purpose the C wire as a W2 wire, and use the PEK to compensate for the missing C. The energize on cool setting was correct. They then had me move the Y1 yellow wire to Y2 and see if A/C would work with the Stage 2 HVAC test. The fan runs constantly even when the ecobee has it turned off. Also connect the red of the AC control cable to furnace Y1, and the white of the AC control cable to furnace C. The ecobee needs a C wire so i removed the BLACK wire from the R terminal (thinking it was redundant now), and left the Red wire on R. And that the best approach is to manually configure staging to get longer stage 1 runtimes. Seems like a high voltage level. Without that jumper between Y1 and W1, the compressor would not turn on during a call for heat. Turn it above room temp. The spare piece of wire, one side goes into the C terminal of the ecobee. Mar 20, 2022 · A bad thermostat wiring is a common reason your Ecobee is not blowing cold air. Oct 14, 2024 · I'm experiencing an issue with aux heat not working, but both the heat and cool heat pump functionality is working fine. Investigate Threshold settings On the thermostat Jun 26, 2021 · I’d like to replace the old thermostat with an ecobee3 lite. No, O/B is the reversing valve to switch between heat and cool. Troubleshoot your ecobee thermostat: Ensure the Y1 wire is securely connected to the Y1 terminal at your ecobee. My WiFi is working fine. The C-wire was plugged in but I later found it’s not connected on the heat pump side (hence the battery powered thermostat). The non fused disconnects go in upside down and that's off there will be an on off opposite each other. If anyone is coming here in the future and you have spliced wiring. In either case, there is always a reason. 24 votes, 16 comments. I think I remember it goes on PEK when using PEK. When there is a call for Y1, the blower motor will turn to low speed setting. " Ruud Condenser UA16AZ36AJ3CA - apparently this is a 3 stage. I am assuming I need 4 ecobee thermostats (well I guess I dont I could get away with 2 but it makes sense to have 4) Here is my question, I can do one of two things. For now the Nest is working and I opened a case with Ecobee as well. Standard wiring - Red to Rc - 24V Blue to C - Common Green to G - Fan Yellow to Y1 - Compressor The answer to the question of whether the ecobee thermostat is compatible with Lennox systems is a resounding yes! ecobee works with Lennox’s ComfortSense 7000 and 5000 series of thermostats, allowing users to easily control their home’s temperature and customize settings to their individual needs. The Y terminal on most furances is a "dummy" terminal. I installed the ecobee 3 lite, and the AC kicks on, but is not cold. See if you have extra wire in your thermostat otherwise it won’t work. There was extra 2 wires not used. Understanding common issues with ecobee heat pumps helps you troubleshoot more effectively. I did not have to uninstall the extender kit. If yours is setup that way, maybe the Ecobee is running the fan after the burner shuts down to get every last ounce of heat out of the system. Dec 31, 2024 · Common Ecobee Thermostat Issues: Learn about frequent problems like incorrect settings for heat pumps, frequent auxiliary heat activation, Wi-Fi connectivity issues, and how to resolve them. AC will not work without a wire going to Y1. Connect Sender Purple to old Boiler White. Open the Ecobee app and navigate to your thermostat settings. Ecobee to the rescue. When engaging your air-conditioner compressor, the ecobee will energize the Y1 connector, so you'll want to make sure you have the correct wire in the Y1 connector. C is 24 VAC common and is frequently blue. And C provides a return path for the current back to the furnace transformer. One white is labeled Y1, red RC, green This is easy. A subreddit for Heating, Ventilation, & Air Conditioning Technicians. Nov 16, 2024 · Updating Your Ecobee: Keeping It Up-to-Date. Currently using a transformer to power the Ecobee for heat. Thanks Tester101 for pointing this out! Perhaps a relay could be your solution, too, for your ecobee's Y1. The old furnace and AC were only connected to the Ecobee with 4 wires: Rc, Y1, W1, and C. Lack of Power Supply. It used to detect it just fine. If Ecobee does not detect G wire that it did before, either your ecobee is bad now or G wire came lose at the other end or you now have a bad air handler Easy to check if you short Rc and G you should get air coming out your vents, even with AC unit not running. A lack of power supply can cause your ecobee heat pump to stop working. Like wow, you guys really know how to Ecobee! I have a new Ecobee Smart Thermostat Premium connected to Goodman heat pump and air handler with two banks of electric heat. I tried A/C yesterday and it does not turn on. I agree that it does sound like aux heat is not kicking in. I don't see a problem with leaving it in test mode, main harm you could do in test would be turning things on and off too fast. You don't necessarily need a PC to be a member of the PCMR. The 2-conductor wire for this has one connected to the C terminal but the other one does not go What equipment does it think you have? The g wire is for the fan in the unit not for cooling. That is why I mentioned using the PEK. 3°C) below the heat setpoint. After reconnecting all the wires to the Ecobee3's terminals, I turned back on the breaker and reconfigured the setup in Settings. The temperature sensor measures the temperature in the room, while the occupancy sensor detects movement to determine if the room is occupied. -If you do see a Fan Icon there, it means the ecobee thermostat is calling for the fan to run. EDIT: If you can remove the section of green terminal block with the four wire holes from the board, slide it to the left so that the terminal block sits on the G, W1, W2, and Y1 holes, then move the wiring so that you have R C G W1 Y1 hooked up at the I have a coworker who had the same issue happened and found out about an ecobee safety setting that won't allow the compressor to kick on if the outside temp is below the default setting, the thermostat is set to 35F by default, and it has been below 34F in my area so after changing the setting down to 25F my heater has been working fine. Hey, thread necromancer here. Or a problem with heat strips. When it fires up the voltage drops to 24. Stopped detecting y1 wire. The blue wire is now basically a common, and the ecobee3 powered right up and has been working as expected since. I do not believe the units can be damaged by mis-wiring. Feb 19, 2023 · Another reason why an Ecobee thermostat may not turn on after install is because of a blown fuse or tripped circuit breaker. Software updates can fix bugs and improve performance. The Y1 wire from the thermostat is Troubleshooting Ecobee Thermostat Issues: AC Not Working | Expert Q&A Update: contacted ecobee customer service. R is 24VAC power and is a red wire. Went back to a Nest after using the ecobee with the extender kit installed. Except the heat is a gas furnace. Also in your original thermostat you did not have a y2 connected and on the ecobee you do. Outdoor unit won’t fire up. Outside (unit) to inside (ecobee) i have the following: -R to RC -C to C -G to G -O to O/B -W2 to W1 -Y1 to Y1 -E to W2 Currently it is blowing cold with no heat pump fan movement on auto/heat setting with equipment showing “stage 1 heat” and “fan”. You will then be prompted to modify the selected wires. Hello, I've just taken my aprilaire ventilator controller out and tried to wire my normally closed damper into the ACC+/- as a 2 wire setup but it's not opening. Electrical Requirements. If these three checks do not work, then you have an issue at the furnace. Some installers use the G fan wire for Common to save the work of adding another wire because most blowers automatically energize G with a call for heat or cooling. Yes. You should use the PEK. If the device is not correctly calibrated, it cannot maintain the temperature setting and present the accurate temperature. Maybe one of the stages is miswired or nonfunctional? Or maybe they're working and wired OK but the ecobee isn't escalating to stage 2 like it should. How to check an Ecobee thermostat wiring Firstly, pull off your thermostat from the wall and ensure that that Y1 terminal has a wire Can I make this work by connecting the five wires between the Ecobee and the furnace control board section for a "conventional" thermostat? I think I'd connect from Ecobee to the furnace: G --> G; W1 --> W1 Y1 --> Y1, which then runs to the AC unit outside C --> C, which then runs to the AC unit outside Ecobee is saying I can't use Y1 without using G. Getting luke warm air with heat setting or sometimes when really cold, just not turning on. The wiring diagram from the service manual shows that for a single stage compressor there should be a wire between Y1 &Y2 at the board and then Y1 runs to the TStat Link. Cap off old boiler Red wire (not used). Ecobee support was super helpful, but couldn't find a fix for my issue. . Unless system is wired for communicating ex: r, I+, I-, c, this is what you would have saw at thermostat terminals but sounds like you had standard r,c,g,y,w then you That is 7 wires. We’ll look at the compatibility of ecobee with some of the common systems. Oct 29, 2018 · It's not working. Furnace Not Turning On Jun 27, 2021 · The yellow Y at the ecobee thermostat is still connected to C on the control board (the AC compressor relay is wired inline with the Y terminal back to the common on the control board). Y1 and Y2 control stage 1 and stage 2 of your compressor. Heater seemed to work, but after a few tests, no power is coming out of the furnace to the thermostat. If you don't have one, check for spare wires and connect one to the on your HVAC control board. Customer: Hi Richard! I'm having a hard time installing my Ecobee thermostat with my Trane Air Handler. Did you recently change or upgrade your thermostat? If so, you will definitely want to double-check your thermostat wiring. Sep 25, 2024 · Common Issues With Ecobee Heat Pumps. Specifically the extra wires on Y1 and Y2. Check your ecobee thermostat: Ensure the thermostat is calling for heat by checking the flame icon on the ecobee. I've done a search and there are a few threads on this topic, so we are not the only ones. Then I bought Ecobee premium, rewired with all 8. 3. The Ecobee is a conventional thermostat. Ecobee SmartSensors use a combination of temperature and occupancy sensors to provide precise readings. Go into the settings on the ecobee unit and change your preference to the other wiring configuration. How Do I Update My Ecobee Thermostat Firmware? Navigate to the settings menu, select “About,” and then “Firmware Version. Hands down an awesome experience from the tech on Ecobee Facebook Messenger support. Y1 & Y2 suggests you have a two stage system. For Smart Thermostat Lite Owners. Edit: Above was So the FV4C air handler supports 3 modes of fan speed, 100%(cool only), 80%(cool + dehumidify) and 50%(super dehumidify, dehumification only) . Else there's tons of enthusiasts with proper equipment to dissect it if you send it to them. Go to Main Menu > Settings > Installation Settings > Thresholds. Should have a Y1 and if you have a heat pump, OB should be the orange wire to energize the reversing valve. Looks like a Carrier furnace circuit board according to the number CEPL130590-01. I do not have a C wire. No difference. My old trane thermostat has a heat pump and the following wires: X2 - orange wire W1 - white wire G - green wire O - blue wire B - black wire Y - yellow wire R - red wireMy new thermostat has the following terminals with the current wiring I have. Problem solved. The only way to make it work is to change the wiring not only at the thermostat, but at the furnace motherboard as well, and the AC motherboard as well if you have an ac. I had similar issue with one of mine but it worked fine after manually enabling the g wire. My company deals lennox(not my choice) did you have an S30 lennox communicating thermostat before the ecobee? If no then you aren’t losing anything by putting the ecobee on. I noticed something with the Y1 & Y2 connectors. Brief summary: Rc, G, C, and Y1 from the AC air handler, and Rh and W1 from the two T terminals of the Taco box corresponding to the heat zone I want to control. Double-check the wiring at your furnace/air handler control board for consistency. I could not remove the black wire out of the slot and I did not open my furnace. Yeah, hopefully just a setting in Ecobee to adjust. I would do something different with the ecobee, such that you have a separate W1 conductor. And I connected the Black to C (common, right?). The Y1 connector is being more sensitive than the W1. Looking at the compressor diagram, especially notes 4,5,6, it looks to me like the Y1 (yellow) and Y2 (blue) wires are connected correctly. , which is also handy when there are power surges. I also have a Ecobee 3 Lite thermostat paired with these units but I can't get the heat to work. It will not able to provide the maximum efficiency of the system and will not communicate with the software. So there is no C wire for the AC. If it also happened with your last thermostat then seems like it's not the Ecobee. According to the diagram on my furnace, the C wire is brown. Y/Y1 and Y2. Start by checking the circuit breaker to ensure it’s not tripped. Dec 21, 2021 · It’s frustrating when you take time to install an Ecobee thermostat only to have it not power on. Calibrating the thermostat is easy and should be done once a year. Here's how I wired the Ecobee: Rc - Red G - Green Y1 - Yellow O/B - Blue C - Brown W1 - Black The diagram on my furnace (Rheem Rh1P3617STANJA) tells a different story. That's plugged into the Ecobee on the C and RC terminals. Your white wire isn’t connected. On the ecobee Thermostat. Started investigating the issue by manually connecting the wires. The technician commented that they would need to figure out the correct thermostat wiring when they install the heat pump. If you only have 1 Y wire at your thermostat just use it in Y1 on the ecobee, doesn't matter if its Y1 or Y2 at the control board side Reply reply More replies More replies Confident_Speech3010 I'm not sure what you mean by "outdoor unit was running the aux heat". Connect Sender Black to ecobee C. So, here are some solutions to help you fix Ecobee Aux Heat not working. As you can see, there are 2 wires at the Y spot Diagrams and step-by-step instructions for installing the PEK for all ecobee models can be found on the ecobee app (available for Apple and Android devices) If you have an unused wire at the thermostat, you may be able to use that as the C/Common wire instead of installing the PEK. Take R and W and put together to see if you get a call for heat from the furnace. If I use the RC from the AC side, there's no power to the Ecobee. Verify the correct wiring at your furnace/air handler control board or old thermostat and ensure that the wiring at the ecobee matches. 5°F (0. These wires will be highlighted in white. The only way the ecobee will work is to change the system preferences to 1 stage or try with another brand, like Bryant. Don't touch AC Red, Yellow, Green on the AC/Boiler side. The Bosch IDP Y1 and Y2 wires control fan speed only: The IDP supports two stage fan control which requires a two stage thermostat (Y1&Y2). A blown fuse can also cause your Ecobee to not turn on. By closing that switch Y1 now has 24V on it. 152K subscribers in the HVAC community. Connect AC G to ecobee G. com on the web. I just replaced my Honeywell thermostat - everything was working. Full check would be Rc+Y1+G and you should get AC and air handler fan on. The Switch+ temperature sensor issue made me think bad thoughts about this but kudos to ecobee for continuing to support the product, which really is a good one now that the Alexa issues -- old and new -- have been worked out. The Personal Computer. If Y1 is not highlighted, select the “No” option on the bottom left because this wiring is not correct. Also make sure power is off to the furnace before moving any wires. It's not about the hardware in your rig, but the software in your heart! Join us in celebrating and promoting tech, knowledge, and the best gaming, study, and work platform there exists. If ecobee really wants to improve their products they should ask for those DOA parts back to their lab to do failure analysis. He did ask me to try to trigger the system by twisting the 3 of the wires: red, orange (now stripped) and another wire (I don't remember, sorry). Ecobee is a home automation device which comes with a touchscreen display. We just bought and moved in Trane G - Fan = Ecobee G - Fan terminal. They are not allowed by forum rules - Thanks. Nov 30, 2021 · Select the one that is appropriate for your type of HVAC system. Same old problem. It provides easy control over your HVAC system via Wi-Fi, mobile app, and Alexa voice service. Nov 14, 2024 · Why Is My Ecobee Thermostat Not Turning On? Check the power source and ensure the thermostat is properly connected. If I was at work 20 miles away it still won't work and tech support gives you the runaround like they are working on it which is a lie. When there is a call for Y2, the blower motor will turn to high speed setting. The PEK needs to be before the control panel. The fan is a single speed PSC fan so not sure what is going on. You must connect Y1 and Y2 (and not jump them at the unit) to get two stage fan operation. Verify the two wires coming from your outdoor compressor unit are connected to Y and C terminals on the furnace/air handler control board. It is also compatible with most gas and oil systems. When I looked at the board Y1 was run to the TStat and Y2 was just empty Link I'm working through this same project right now also. If the AC kicks on, you have a faulty Y terminal on the base plate of the ecobee. The C wire on the furnace was not connected to anything on the honeywell thermostat. Without those connections, your thermostat would not be able to control the condenser. We do not work in Amps or DC voltage. I think I’m just going to pull new wire anyway. I re-installed the Honeywell and it works fine again. I just moved the wires on the back of the nest like they were on the ecobee. If they work, then the thermostat is bad. Another Redditor posted about 6 months ago, with exactly the same system and setup as you, you may want to check out that post and my reply. Now I have Y 1 and Y 2, As well as Aux 1 and 2. What's connected to Y1 if you don't have an air conditioner? To control both stages of heating both W1 and W2 have to be connected. Next time when this issue happens again, check for the following: Quick Change > Equipment Running Now > -If your blower fan is running, and there is not Fan icon under Equipment Running now, it means the ecobee is not calling for the fan to run. Few reasons seemed to out of the conversation - the rate of API calls from non partnered integrations was expensive, the Ecobee Webapp provides much of what they say in HAS deployments and their roadmap. The correct setting on the Ecobee thermostat for when to energize the valve (either energize on cooling or energize on heating) will need to be selected to make sure that the heat will work. So before Ecobee could call me back, I decided to run a jumper between the Ecobee3's Y1 & W1 terminals. They then had me switch the yellow wire to the G port and put the green wire in the Y1 slot and plug ecobee back in to see if it would make the fan run and it did. ecobee will work with 24VAC controls without any hitch. I wired everything up, not needing the PEK system from Ecobee as there were extra wires ran so I utilized the C wire again to the Thermostat. true. I think it's ecobee's terminology that is at least partly at fault. Is my Jan 15, 2024 · Does ecobee Work With Any AC System? Your ecobee will work with most of the common heating and cooling systems. I believe the setting is only accessed through the thermostat (not the web portal). Don't see any 'aux' heat options in the settings anywhere. And I ran the Y, W,R,G, and C(Black) from the furnace to ecobee Y1,W1,Rc,G,C. Connect Red from AC to Ecobee Rc. Y1 turns compressor on. I would double check your Y1 is connected properly and confirm that it knows there is at least single stage cooling available. Ecobee has been junk as of 2020 when it stopped working on Samsung phones. The update is now rolling out. My previous set up with Nest was 6 wires, jumped between Y1 -Y2, so it was always calling for stage 2, but fan speed was slow some reason. I’ve set the HVAC to control the fan, as some people have reported that being an issue. Just replace the fuse and switch the breaker back on if it has tripped, and you’ll be all set. If it’s working with your old tstat, it should work fine with the ecobee. If the outline of the flame icon is white, it's not calling for heat. May 31, 2023 · Connect the yellow of the thermostat cable to Ecobee Y1 and to furnace Y. Right now I have Rc, C, Y1, G, O/B. The Y2 is for the 2nd stage cooling. or Dec 3, 2024 · Had a pretty unsetting call with Ecobee support confirming that they are not longer providing dev accounts. I believe that is the correct one. Trane W - Aux heat = Ecobee W/W1 - Heating terminal. How to Fix Ecobee Thermostat Not Turning On: The Ecobee thermostat is a popular choice for smart home climate control, offering advanced features and energy savings. Download and install the update. Here’s how to update your Ecobee: 1. But, your comment about the wires not matching got us hunting, and we found some splicing going on between the thermostat and the furnace. Heat works, fan works but not getting the AC to kick on. ༼ つ _ ༽つ I don’t see Settings but under Account I did Log Out and back in, but that didn’t fix it. Using iPadOS 16. 3. Trane T - Outdoor temperature compensating thermostat sensor = Not used on Ecobee thermostat Trane R - Hot power = Connect trane R terminal to one of the Ecobee RC terminal. The heat pump will run the outdoor unit and the aux heat would be your secondary source. Close the blower door, wait for the Ecobee to start, and set it to Cool with a temperature lower than the current room temperature. This Ecobee3 Smart Thermostat can increase your home’s comfort and energy efficiency. Here's the original wiring of the HVAC Control board. Maybe this is the problem? Ruud COIL RCFZ3717STANMC A subreddit for ecobee and all their smart home products. Nov 3, 2022 · If your Ecobee was working just fine before and had only recently started to malfunction, then it is likely that the circuit might have tripped. If you do that the cooling part will not work. Figured I'd have to re-wire the air handler. 2. It uses R C W Y G terminals. Verify the HVAC system is functioning. I'd steer clear of ecobee. If you do not have sufficient thermostat wires to connect both Y & G, place a jumper between Y and G" It also brings up this youtube video with a "fix" for E150 that basically states the above as well Diagnostic steps performed: I can activate the fan manually with the Ecobee, I know the G wire is connected properly and working fine. The 5 AM fuses on the circuit control board are susceptible to damage from power outages. W is heat and is a white wire. So I hooked up the Ecobee's according to the diagram, nothing turned on. If you have two stages of AUX heat, you will connect AUX2 to W2 on your ecobee. Now when your Stat calls for cooling it closes a switch from Rc to Y1. Works ok when using the ecobee. Your Ecobee will automatically notify you if an update is available. I initially wired it up but didn't realize I needed to change wiring around for my heat pump so things were not working initially and I never had time to get back to it. Without that, on many/most systems, the fan will not run, and you will have no cooling. The only difference is the Honeywell has a jumper between the Rc & Rh terminal. The Ecobee recognizes everything and acts like it is working, but the heat pump is only blowing lukewarm/cold air. Dec 2, 2022 · One was the original installer. I wired the ecobee according to this dual transformer wiring diagram on ecobee’s site. If only W1 is connected then depending on how the furnace's control board is configured, either you're never using the second stage, or the furnace is automatically switching from stage 1 to stage 2 after running for a certain time. Jun 2, 2023 · I have an Ecobee smart thermostat installed and it is not communicating with the AC. Check for available updates. If you change the "Comfort Setting" mode to anything (home, sleep or away) it will "hold" in that mode until you manually change it. This assumes that your ecobee's Y1 isn't damaged already which you could test by temporarily moving your G (fan) wire to Y1 and running a test for AC—if the fan starts then your Y1 could still be working and, along with a relay such as RIBU1C, could still yet run your AC. I have a 2 stage carrier and my ecobee 3 lite staging set to auto. All over this sub the consensus is that ecobee auto staging just runs stage 1 for 10 mins then switches to stage 2. They go to the condenser (outdoor unit). ” Had the same problem; worked for me. The Y1 voltage at the compressor is 25-26 Vac. Jun 19, 2021 · I’d like to replace the old thermostat with an ecobee3 lite. x volts between Y1 and RC. Oct 15, 2021 · I'm installing an Ecobee 3 Lite thermostat. Dec 3, 2024 · Had a pretty unsetting call with Ecobee support confirming that they are not longer providing dev accounts. Your PEK needs to go at the splice, not the furnace. If your ecobee thermostat won't turn on, follow these steps to troubleshoot the problem. Connect AC Y to ecobee Y1. Then try the heat. Most of my Switches have rejoined Alexa without the need to contact ecobee. Heat and AC. First run outside and check the disconnect box. If it’s not a heat pump, just connect Y1 terminal. R & Y to check for A/C, R & G to check to see if the fan runs. Connect Sender White to ecobee W1. Not two separate wires, just a physical jumper between the terminals Apr 23, 2023 · Well, Ecobee units draw power from the furnace, meaning any disruption that causes power loss at the furnace will result in the Ecobee not working. Next, you’ll see all of the wires detected by Ecobee. When calling for heat the FET terminals within the ecobee will communicate 24vAC, no more, no less, to the W1 During the initial installation or during reconfiguration, there will be a screen displaying the wires your ecobee has detected. For newly installed Ecobees with no power, check the thermostat’s placement on the backplate. Yes, R>RC, C>C, Y1>Y1, and W2>W1. However, like any electronic device, it can sometimes encounter issues. Not really, it still only works intermittently for me. just Yes I have a 2 stage system. com Looks like I’m only getting 17. Before Configuring on the ecobee. So in the attic I rewired both air handlers, fan turns on, heater runs greats, when ac should turn on fan kicks on, but the outside condenser does not. I have ecobee's on 3 houses over the last 5 years with no problems so would not say it is a general design problem. I have (5) wires: R, C, W, Y, G I installed the ecobee 3 lite, and the AC kicks on, but is not cold. For your If you have two stages of AUX heat, you will connect AUX2 to W2 on your ecobee. One common problem is the thermostat not turning on. Because of the splicing there was some crossed wires. Not sure what to do here. Y is cooling and is a yellow wire. However, ecobee3/4 won’t allow this for safety. Ecobee 4 w/24v Transformer. There was previously a jumper from Y1 to Y2 which I left in place. Everything is working fine with the furnace. What you need is a spare piece of thermostat wire. Unable to display any information in the Home IQ section of the app. You also need to verify that the ecobee was reconfigured correctly to support your new equipment. One or both issues mentioned above lead the AC unit to work inefficiently, which costs greatly, wears, and tears more parts of the unit. With a 2 stage Y1 is like low, Y2 is high. See this Ecobee Article If anyone happens to be using the Ecobee Smart Enhanced with the Bosch IDP, find the installation instructions "Inverter Ducted Packaged Heat Pump Bosch IDP Premium" and look for the 2H/2C working. Aux works fine. The ecobee and the furnace control board wiring look right. ” Follow the prompts to install updates. Nov 3, 2023 · The original connection was R/C/Y1/Y2/W1/G which made Heat Stage 1 and A/C 2 Stage. I noticed on my boiler (120V & a completely different system) that the transformer also puts out 28VAC. Odd problem. When the heat strips are on heating the house when it us too cold for the heat pump, they will struggle to keep the house at the set temperature. Apr 19, 2022 · However, recent issues with the Ecobee Aux Heat not working have annoyed many owners. Inside the furnace, I have the five wires connected to R, C, G, W1, and Y1. Their techs will tell you're they're working on it and they are full of it. I looked up the diagram from the American Standard website for each of the units along with EcoBee's installation guide. When the desired temperature is set below the actual temperature, the pump relay is triggered for a time period between 30 and 120 seconds, before Heat pumps can have a hard time working when it gets below freezing, so you have heat strips in there to supplement the heat. I also have two additional wires that were not used by the Honeywell thermostat: a white wire and an orange wire. Moreover, when I tried the AC with the old thermostat with the wiring shown here it works perfectly fine, even the compressor. I really wanted to go with the new Ecobee as the Nest was starting to get flaky with me so I may have to get someone out as you suggested. The only difference is the Honeywell has a jumper between the Rc & Rh. Sure enough, fitting two wires into Y was difficult, but I did eventually get them in. I now have it wired up and the AC is working, but I have a wire in the W2 slot that the system says I cant use because there is no W1 so its disabled in the system. Support had me send them a photo of my wiring then call them. I used the white wire in the G terminal for Hello Ecobee community, over the weekend I purchased and installed an Ecobee 3 Lite with 2 room sensors and all was going well till this morning. What questions should I ask them to get this low voltage issue resolved? Please do not add prices to your posts. Now go to the thermostat side. I am assuming the pek goes into the zone board and not the furnace directly. I'm wondering if the yellow wires may be loose somewhere Just installed an Ecobee and not sure how to wire this or set it up. All in all, it is worth noting that the Ecobee room sensor comes with a 3-volt CR-2032 that keeps it running when there are power interruptions. To get Heat Stage 2, they repurposed the G wire to W2 at the stat and on the board. For example using a RIBU1C, connect its 10-30 VAC coil with its Wht/Yel wire to C of the AC system and Wht/Blu to the ecobee's Y1. In heat pump systems, Y1 controls your compressor, which heats and cools your home. I installed the thermostat originally with the PEK (eveything worked minus the outside unit running, by the way we have a furnace) because I didn't think I had a C wire, but after pulling some of the wires behind the thermostat I think I have one (it's blue). I was just wondering if anyone knew if it would still work using the PEK. If you are not a member of the trade… Did you measure 10v on Y1 without the Ecobee connected? I will have to measure mine. I have a Y and a Y2. G is fan and is the green wire. Check out the list below. The HVAC unit will detect that 24v and turn on the cooling mode. Ok the Lennox is a communicating thermostat. R to Rc, Y to Y1, G to G. They are not compatible. Thank you! You spurred us to dig deeper and we solved the problem. Since new you can try returning to the store and swapping out the Nest. Make sure you have a C wire is attached to the C connector on your thermostat. I think my wiring is a little odd Here is how it was wired previously: Original wiring. Here are two primary problems often encountered. I'm in desperate need of help, I have an American Standard HVAC (TEM4A0B36S31SB) and Heat Pump units(4A6H4036G1000A). The technical reason this will not work is because you cannot /not/ have a "G" wire, because the thermostat is responsible for energizing this during a cooling call. Yellow and black were not connected to my perfectly working Nest. Then connect its N/O (normally open) output to the AC system: Yel to R and Org to Y. Also had it tell the ecobee I had a g wire to setup. Even though this issue is pretty rare, you will still notice a sudden drop in the performance of your HVAC system. It’s not a long run and should be easy. The new furnace was installed last week and the heat pump is going to be installed later today. Trane Y - Compressor in both heating and cooling = Ecobee Y - Cooling terminal. Otherwise if you can't add a C wire at the Nest then try adding a resistor at the furnace connecting the C and Y. The unit also has a spot for a g wire, the old thermostat just did it use it. I have a fairly simple setup compared with what I see some folks have here. The ecobee3s work properly when wired to the boiler. saying they don't like Ecobee. There were 5 wires plugged into the thermostat (I forgot to take photos!), which were W1, Y1, G, and R. Automatic versus Manual Threshold Staging: By default, ecobee thermostats will have the Configure Staging option set to Automatically. Like change it from “Rc and Rh” to “Rh only. Be sure to test both heating and AC or you might have a surprise when the seasons change. The tech said that the lack of G means the blower does not start prior to the condenser starting so it turns on but then turns off. Does not take much to blow a fuse on a control board. That "type" of hold will not be changed by the schedule, even though you have your "hold mode" preference set to "until next scheduled event". I know there should be two more wires for the A/C unit - one to C and one to Y1 but that is not the case. If you Google it you will see that the “C” terminal is beside the “R” terminal, so it looks like that blue is on “C” and if it goes up in the bundle to the thermostat you should be good to go to use that as your “C” on the Ecobee. The equipment in play is: Ecobee by Bryant Smart Thermostat; 38MURA Bryant Heat Pump; Amana AMVC96 Gas Furnace; Wiring: Thermostat -> Furnace; Rc -> R (outdoor unit also tied in with wire nut) G -> G I just replaced my Honeywell thermostat - everything was working. The full wiring is Ecobee <-> Cooler W2 <-> W Y1 <-> Y R <-> Rc G <-> G What we are now seeing as a result is that the Ecobee 3 sees the system as a one-stage air conditioner, and it operates in the following manner. It is working better than Nest, furnace fan is quiet at Y1 and blasting at Y2. By default, ecobee engages heating when the temperature drops 0. Manually add the Y1 terminal so that it’s highlighted. 1. With the Ecobee we transfered all the wires like we found them, except that we got rid of the jumper connecting Y1 to W1 and then we moved W2 (single stage furnace) to W1 on the Ecobee. Go to Main Menu > General > Settings > Installation Settings > Thresholds. What equipment does it think you have? The g wire is for the fan in the unit not for cooling. It’s even more frustrating when the thermostat was already working and suddenly loses power. I had written ecobee and this is what they wrote back, in case it is helpful. First verify that the wires are firmly connected behind the ecobee but tugging gently to make sure they are not loose. You just lose thermostat control of the fan. My setup is a heat pump outside (old Trane XE900) and some form of air handler inside. I'm just a homeowner, not HVAC tech, so take all of this with a grain of salt. "The ecobee can take anywhere from 24-29vAC from your HVAC unit. You need to verify that all the wiring and voltages are correct. In conventional cooling systems, Y/Y1 controls the first stage of cooling and Y2 controls the second stage, which helps cool down the home faster. Little more backstory: I’m trying to replace a battery-powered thermostat with this Ecobee. I would repurpose the C conductor as a separate W1 conductor at both the thermostat and furnace control board. Changing the wiring for AC as shown here does not work (I removed the white wire and placed it in Y2, in Y1 very hot air comes). I needed to add the PEK at the HVAC control board. Both recommended replacing the thermostat. R to Rc (red) G to G (green) Aux to W1 (white) Y to Y1 (yellow) B to O/B (brown) C to C (blue) My heat pump has been working just fine until now (with my old honeywell) but when the ecobee calls for heat only the fan will turn on. How to Fix Ecobee Aux Heat Not Working? Check Heat Thresholds Jan 11, 2024 · I previously had 2 dumb thermostats. There is light air that comes but the outside unit/ compressor does not turn on. You just have to love PCs. Make sure it's in properly and if it's a fuses type the fuses are good. The Ecobee has the ability to control the fan instead of the furnace controlling the fan. If you install it, test the heat, and just cool air blows out then try setting the valve to energize the other way. Two Pek on each zone of the zone board to feed back to each thermostat on that furnace. The other side goes into the wire cap that currently has two wires in it already. See full list on robotpoweredhome. If you have no spares, install the Power Extender Kit (PEK). gnxaliy hftej rfrudn unnhr gfrr nhjt xiqdwve itobpa wfrz aqay